Coriolis µ is an innovative biological air sampler for bio-contamination assessment, mainly dedicated to air quality control and air quality monitoring in environmental and pollution research, the pharmaceutical, food and veterinary industries, in biomedical and health environments, and so on. Based on a cyclonic technology, combined with a high air flow rate, Coriolis μ offers the most efficient particle collection in 10 minutes. Biological particles such as toxins, viruses, bacteria, molds, pollens and spores are collected and concentrated in a liquid ready to be analyzed with microbiological and cellular and molecular biology methods.
Virus collection & detection
Coriolis air samplers can also be used to detect viruses in air samples. Virus-laden aerosols sampling presents many challenges. As viruses are often present at very low concentrations in the air, a large volume of air has to be collected to have reliable results. This can translate in an extremely time-consuming process —sometimes up to a week.
Thanks to its high flow rate – up to 300L/min– the Coriolis μ air sampler can be used to collect air samples for airborne virus detection in a few hours. Through its unique liquid cyclonic technology, it can collect viral particles in a chosen collection liquid. Coriolis μ samples are compatible with all rapid microbiology techniques such as qPCR or microarrays, and also NGS analysis. Virus concentrations as low as 100 genomes copies/m3 can be detected in collected air samples.
Weight:
- 3 kg (with battery)
Dimensions:
- 22 x 33 x 36 cm
Air flow rate:
- 100 to 300 L/min
Collection time:
- 1-10 min
Collected particle sizes:
- from 0.5 micro meter
Liquid output volume:
- 15 mL
Autonomy on battery:
- 1 hour
Decontamination:
- Hydrogen peroxide
Catalogue number:
- P001080-CORM0-A
Access to alternative technical analysis:
Thanks to its liquid collection media, Coriolis technology gives access to highly sensitive and specific results in only a few hours thanks to its compatibility with all biological standard methods, Culture, PCR, QPCR , ELISA, and more.
Split up your sample for different analyses:
With a consistent liquid volume of 15 mL, Coriolis prevents any saturation of the liquid media. It also allows the user to split up the final sample and thereby make several analyses which guarantees the representativity of the trials by testing the repeatability of the results.
Bio-contamination results beyond cultivable flora:
Analyzing by culture only allows users to count micro-organisms able to grow on agar dishes. However some biological particles in the air are not cultivable. By allowing the use of alternative techniques, Coriolis enables the count of total flora beyond the limit of cultivability.
Long time monitoring:
Air quality monitoring during a whole production process in aseptic zones or biosphere control can be critical. Coriolis equipment allows for continuous monitoring of the environment for up to 6 hours.
The Coriolis µ is based on an innovative and patented technology.
The principle is to transfer the airborne particles into a liquid sample. This liquid sample output allows users to overcome the limits of traditional methods, particularly since Coriolis technology differentiates from impaction in relation to three main parameters:
- high air flow rate to collect efficiently even very low diameter particles such as viruses – 300 L/min
- long time collection to monitor an area for several hours, a whole batch of production – up to 6 hours
Compatibility with any analysis method Products:
- Sterile cone prefilled with specific liquid sample
- Air is aspirated and drawn into the cone forming a vortex
- Particles are centrifuged into the wall of the cone and separated from air
- Contaminants in the liquid sample are ready for analysis
Long time monitoring option:
Bio-aerosol samplings with Coriolis µ are limited to 10 minutes as evaporation naturally occurs during collection. The long time monitoring option allows users to maintain the collection liquid volume at a constant rate over the entire sampling period. Air sampling can be done over an extended period of time (from 1 minute to 6 hours of collection) to assess biological contamination.
This option converts the air sampler Coriolis µ into air monitoring equipment that provides new possibilities for investigation into biodiversity, indoor air quality, outdoor biological pollution air monitoring, the veterinary and food industries or biomedical and health facilities. The user manually sets the injection rate for collecting the liquid automatically poured inside the cone during air sampling.
Traditional value is 0,6mL/min in a standard environment. The device can be paused to control the adjustment of the liquid level. This option is compatible with any Coriolis µ – a software upgrade is required. The Coriolis μ shipment box is designed for nomad sampling or storage. In double-walled robust plastic, it can be used for multiple shipments to the sampling site.
REASONS TO CHOOSE CORIOLIS MICRO – AIR SAMPLER
The most efficient concentration of biological particles
High Air Flow Rate & Long Time Monitoring option – Up to 6 hours
Compatible with all downstream experiments – divisible samples for several analyses in parallel
Flexible liquid sample output