HIGHLIGHT
Upto 210mm specimen height accomodation
The innovative software functions of Remote pendant
Digital/optical image evaluation combined with intuitive operator software
A rock solid frame structure
Micro system controller
Electronically controlled loads
Collison Protection System (CPS)
Hardness scale | (Micro-) Vickers, Knoop and Brinell |
Load application | Multi Load cell, force feedback, closed loop system |
Load range | Model specific |
Specimen height accomodation | Up to 210mm |
Motorized turret | Six positions: Fitted with up to two indenters, four objectives |
Optical system | Optional |
Objectives | Optional objectives |
Electronic system | High performance embedded electronics system running smart touch firmware |
Test loads (depending on model) | 10gf, 15gf, 20gf, 25gf, 50gf, 100gf, 200gf, 300gf, 400gf, 1kgf, 2kgf, 2.5kgf, 3kgf, 4kgf, 5kgf, 6.25kgf, 10kgf, 15.625kgf, 20kgf, 25kgf, 30kgf, 31.25kgf, 50kgf, 62.5kgf |
Vickers test range | HV0.010, HV0.015, HV0.020, HV0.025, HV0.050, HV0.1, HV0.2, HV0.3, HV0.5, HV1, HV2, HV2.5, HV3, HV4, HV5, HV10, HV20, HV25, HV30, HV50 |
Brinell test range | HB1/1kgf, HB1/1.25kgf, HB1/2.5kgf, HB1/5kgf, HB1/10kgf, HB1/30kgf; HB2.5/6.25kgf, HB2.5/7.8125kgf, HB2.5/15.625kgf, HB2.5/31.25kgf, HB2.5/62.5kgf; HB5/25kgf, HB5/31.25kgf, HB5/62.5kgf |
Knoop test range | HK0.01, HK0.015, HK0.02, HK0.025, HK0.05, HK0.1, HK0.2, HK0.3, HK0.5, HK1, HK2, HK5 |
KiC Fracture | KC/1, KC/3, KC/5, KC/10, KC/15, KC/20, KC/25, KC/50, KC/100, KC/200, KC/300, KC/450 |
Indentors | Vickers, Knoop & Brinell certified indenter |
Test cycles | Motorized, automatic procedure |
Standards | Complies to or exceeds, ISO, ASTM, JIS (Nadcap) standards |
Test force tolerance | <0.5% for all forces |
Display resolution | 0.1 HV, HK, 0.5 HB |
Hardness conversion | Rockwell, Rockwell Superficial, Vickers, Brinell, Knoop, Leeb & Tensile |
Statistics | Total test, max, min, average, range, standard deviation, all in real time after each test |
Data storage capacity | Integrated memory system |
Connectivity | USB ports, Converter to RS232, 1 x for ptional integrated CCD camera |
Dwell time setting | Default 10 seconds, user defined 1 to 99 seconds (1 sec increments |
Printer | (optional) |
Manual stage dimensions | Stage 100 x 100mm Travel 25 x 25mm Reading 0.01mm |
Motorized stage dimension | See optional CNC X-Y stage diemnsions in this catalogue |
Operating temperature | 10-35° C, non-condensing |
Humidity | 10-90% non-condensing |
Machine dimensions | 525 x 323 x 773mm |
Machine weight | 80kg |
Power consumption | 75W |
Power supply | 100VAC to 240VAC, 50/60Hz, single phase |
FH-3-31 | 200gf-31.25kgf | Vickers, Knoop & Brinell (large frame) |
Optional: 10gf-200gf | ||
FH-3-32 | 200gf-62.5kgf | Vickers, Knoop & Brinell (large frame) |
Optional: 10gf-200gf |