HIGHLIGHT
Load cell, closed loop system.
Test loads 62.5kgf/612N to 3000kgf/29kN (137.8-6614lbf).
Simultaneous conversion to Rockwell, Vickers, and Leeb rebound testing.
LCD display showing Brinell value, statistics and tester settings, or 7.5in full-color touchscreen on selected models.
Microscope with 20x magnification and analog scale for indentation measurement (analog models FH-9-0, FH-9-1 and FH-9-17).
Standard Brinell digital scanner (CCD camera) for automatic indentation measurement (on selected models).
Extended frame (XL) versions available with 390mm (15.35in) workpiece height and 220mm (8.66in) throat depth.
Horizon high performance PC-based camera indent measuring system. Automatic measurement of the indent on the LCD screen.
Store, file, handle images and data on the hard disk (selected models).
Brinell test range | 62.5kgf/612N (137.8lbf), 80kgf/784N (176.3lbf),100kgf/980.7N (220.5lbf), 120kgf/1176N (264.4lbf), 125kgf/1225N (275.6lbf), 187.5kgf/1838N (413.4lbf), 250kgf/2.45kN (551.2lbf), 500kgf/4.9kN (1102.3lbf), 750kgf/7.35kN (1653.5lbf), 1000kgf/9806N (2204.6lbf), 1500kgf/14.7kN (3307lbf), 3000kgf/29kN (6614lbf) |
Indenters (optional) | Balls 1mm, 2.5mm, 5mm, 10mm (0.0394in, 0.0984in, 0.1969in. 0.3937in) |
Test force selection | Electronic, closed loop, load cell, force feedback system, indication in kgf or N. Test force selectable over menu operation |
Test procedure | Automatic, loading/dwell/unloading |
Test force accuracy | <0.5% full range |
User display | Diameter of indent, length of diagonals, hardness value, converted value, test force, online statistics |
Display resolution | 0.1 HB |
Hardness conversion | Rockwell, Vickers, Brinell, Leeb, and Tensile 2 scales simultaneously |
Standards | Conforms to EN ISO 6506, ASTM E-10 |
Statistics | Total tests, maximum, minimum, average, range, standard deviation, all in real-time after each test |
Control panel | Start test, stop test, dwell time, print, clear, menu operation for date, time, scale and load settings, language |
Memory | Large memory for testing results |
Data output | RS232 bi-directional, USB, WLAN, LAN RJ45 |
Loading mechanism | Fully automatic, closed loop, force feedback, loading, dwell, unloading |
Dwell time setting | Default 10 seconds, user defined 1-99 seconds |
Eyepiece microscope | Analog or CCD camera, depending on model |
Vertical capacity | 220mm (8.66in) standard model, 390mm (15.35in) XL model |
Horizontal capacity | 220mm/8.66in (from center-line) all models |
Operating temperature range | 10-35°C (50-95°F) |
Operating humidity range | 10-90% non-condensing |
Weight | 130kg (286.6lb)/160kg (352lb) XL model |
Power supply | 100V AC to 240V AC, 50Hz/60Hz, single phase |
Power consumption | 390W |
Reviews
There are no reviews yet.