See your real signal
Industry-leading signal fidelity, minimum noise and highest effective number of bits (ENOB) provides confidence you are seeing your real signal and measuring it precisely. High signal-to-noise ratio and low internal noise floor enable you to perform precise characterization of your designs.
- Bandwidth enhancement eliminates imperfections in frequency response to the probe tip
- Low jitter noise floor and high vertical accuracy provide additional margin in your measurements
- Wide range of probes simplify complex measurement setups and maintain signal integrity
- Compare optical and electrical signal timing on one screen with calibrated optical probe
Reduce debug time
From first power-on through operational checks, MSO/DPO70000 Series provides features you need to find problems fast. An industry-leading waveform capture rate and Pinpoint® triggering make you efficient at tracking down and capturing intermittent faults.
Highlights
- FastAcq keeps up with your changing signals to show true system behavior including elusive faults
- Quickly find invalid state or bus sequences with parallel/serial bus decoding/triggering
- iCapture™ easily verifies analog characteristics of digital signals without changing connections
- Visual Trigger saves hours of capturing and manually searching through acquisitions to find critical events and complete your debug efforts
Measurement and analysis tools that keep you on track
Application support packages provide automated compliance testing, insightful debugging tools and the extensive signal connection options you need to verify and certify your latest design.
Highlights
- DPOJET: the most comprehensive, flexible measurement tool available
- SDLA: the most powerful, complete tool for analyzing and compensating for signal affects in serial data links
- Broadest range of standards support, including I2C, SPI, RS-232, FlexRay, MIPI, DisplayPort, HDMI, PAM4, PCIe Gen3/Gen4, SATA/SAS, USB3.1, Type-C, 10/100BaseT to 10G/100G Ethernet
- Powerful debugging tools to quickly uncover/fix design challenges
- Optical measurements, such as Extinction Ratio (ER), Average Optical Power (AOP), Optical Modulation Amplitude (OMA), Optical High/Optical Low value – compatible with DPO7OE1/DPO7OE2 optical probe
Model | Analog Bandwidth | Sample Rate | Record Length | Analog Channels | Digital Channels | List Price |
---|---|---|---|---|---|---|
MSO72004C | 20 GHz | 50 GS/s – 100 GS/s | 62.5M points – 250M points | 4 | 16 | Configure & Quote |
DPO72004C | 20 GHz | 50 GS/s – 100 GS/s | 31.25M points – 250M points | 4 | – | Configure & Quote |
DPO70604C | 6 GHz | 25 GS/s | 31.25M points – 125M points | 4 | – | Configure & Quote |
MSO70404C | 4 GHz | 25 GS/s | 62.5M points – 125M points | 4 | 16 | Configure & Quote |
MSO70804C | 8 GHz | 25 GS/s | 62.5M points – 125M points | 4 | 16 | Configure & Quote |
MSO70604C | 6 GHz | 25 GS/s | 62.5M points – 125M points | 4 | 16 | Configure & Quote |
MSO73304DX | 33 GHz | 50 GS/s – 100 GS/s | 62.5M points – 1G points | 4 | 16 | Configure & Quote |
MSO72504DX | 25 GHz | 50 GS/s – 100 GS/s | 62.5M points – 1G points | 4 | 16 | Configure & Quote |
MSO71254C | 12.5 GHz | 50 GS/s – 100 GS/s | 62.5M points – 250M points | 4 | 16 | Configure & Quote |
MSO71604C | 16 GHz | 50 GS/s – 100 GS/s | 62.5M points – 250M points | 4 | 16 | Configure & Quote |
DPO70404C | 4 GHz | 25 GS/s | 31.25M points – 125M points | 4 | – | Configure & Quote |
DPO70804C | 8 GHz | 25 GS/s | 31.25M points – 125M points | 4 | – | Configure & Quote |
DPO72304DX | 23 GHz | 50 GS/s – 100 GS/s | 31.25M points – 1G points | 4 | – | Configure & Quote |
DPO72504DX | 25 GHz | 50 GS/s – 100 GS/s | 31.25M points – 1G points | 4 | – | Configure & Quote |
DPO71254C | 12.5 GHz | 50 GS/s – 100 GS/s | 31.25M points – 250M points | 4 | – | Configure & Quote |
DPO71604C | 16 GHz | 50 GS/s – 100 GS/s | 31.25M points – 250M points | 4 | – | Configure & Quote |
DPO73304DX | 33 GHz | 50 GS/s – 100 GS/s | 31.25M points – 1G points | 4 | – | Configure & Quote |
MSO72304DX | 23 GHz | 50 GS/s – 100 GS/s | 62.5M points – 1G points | 4 | 16 | Configure & Quote |
Analog/Digital Design and Debug
When you’re debugging your next design, you need to quickly find and analyze a wide range of mixed-signal problems, from signal integrity issues like crosstalk or jitter, to bus faults such as setup and hold violations or dropped packets. That’s when you need an oscilloscope with powerful tools and reliable performance. You’ll keep on schedule when you have an MSO/DPO70000 on your bench.
Highlights
- Easily view analog characteristics of any input and verify system timing with iCapture™ on 4 analog and 16 logic channels
- Analyze system operation on the timescale you need with deep memory on all channels
- Find and fix problems fast with a full suite of triggering, decoding and measurement tools
Data Communications
Today’s data communication networks are constantly evolving and are built upon many different standards. MSO/DPO70000 offers comprehensive, integrated tool sets for validating the physical layer of Ethernet devices and debugging ethernet-based systems from 10BASE-T up to 40/100GB. MSO/DPO70000 also offer advanced compliance and debug tools for other Data Comm standards.
Compliance and debug tools that meet your standards
Explore 400G PAM4 testing solutions
Highlights
- Standard-specific automated compliance testing and debugging tools
- Extensive jitter analysis and debug tool set
- Characterize PAM4 and NRZ signals
High Speed Serial Communications
Next generation digital interface standards push the limits of today’s compliance and debug tools. MSO/DPO70000 Series’ automated measurement suites speed PHY validation cycles and ensure consistency. Powerful tools like Protocol Decoding and Visual Trigger shorten debugging when compliance measurements fail. Identify jitter and noise from crosstalk or other multi-lane noise coupling.
eGuide to solutions for PCI Express, DDR4, USB & SAS/SATA
All high speed serial compliance and debug tools
Highlights
- Accelerate analysis, validation, and pre-compliance testing of your PCIe, SATA or SAS design
- Quickly find the root cause of issues when testing SuperSpeed USB 3.1 Type-C designs
- Decrease DisplayPort compliance testing and HDMI physical layer validation times
- SDLA with DPOJET provide comprehensive simulation and measurement of Computer, Communications, and Memory buses
RADAR and RF
MSO/DPO70000 Series with SignalVu Vector Analysis software gives you the analysis capabilities required to overcome the most challenging RF, wireless and microwave design problems with total confidence. You can analyze signals up to 70GHz wide with the same tools used on Tektronix’ Real-Time Spectrum Analyzers.
Trigger, Capture, Analyze wideband spectral events
Highlights
- Easily verify wideband radar, high data-rate satellite links, WLAN 802.11, WiGig 802.11 or frequency-hopping radio designs
- Make measurements in frequency, time, phase, modulation domains simultaneously
- Application optimized software options supporting wideband radar, high data-rate satellite links, IEEE 802.11 a/b/g/j/p/n/ac (WiFi), IEEE802.11ad/ay (WiGig), Zigbee and Bluetooth
Advanced Research
Get insight into the fleeting and subatomic events that represent the world of fundamental particles. Discover how we’re measuring the world’s first true quantum computer. Find out how today’s advanced researchers are changing the way we live our lives in profound ways.
Advanced research topics
Highlights
- Quantum Research
- Rotational Spectroscopy
- Photonic Doppler Velocimetry (PDV)
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | P6717A | PROBE, GENERAL PURPOSE UPGRADED W/ ACCESSORY KIT | Configure & Quote |
View Datasheet | P6750 | PROBE, P6750 DMAX FOR MSO70K INSTRUMENTS | Configure & Quote |
View Datasheet | P6780 | 17 channel differential input logic probe for MSO70000 with solder-in accessories | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | TCPA300 | Current Probe: 100 MHz, Amplifier (Requires Probe) | Configure & Quote |
View Datasheet | TCPA400 | Current Probe: 50 MHz, Amplifier (Requires Probe) | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
P5200A | High Voltage Probe: 50 MHz, 50X/500X, 1.3 kV, Differential, BNC | Configure & Quote | |
View Datasheet | P5202A | Differential PROBE; 20X/200X, 100 MHZ DIFFERENTIAL VOLTAGE PROBE | Configure & Quote |
View Datasheet | P5205A | High Voltage Probe: 100 MHz, 50X/500X, 1.3 kV, Differential, BNC | Configure & Quote |
View Datasheet | P5210A | High Voltage Probe: 50 MHz, 100X/1000X, 5.6 kV, Differential, BNC | Configure & Quote |
P6250 | PROBE, DIFF HV, WITH TEKPROBE-BNC INTERFACE, 42V, 500MHZ – CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote | |
View Datasheet | P6251 | PROBE, DIFF HV, WITH TEKPROBE-BNC INTERFACE, 42V, 1GHZ – CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | P5100A | High Voltage Probe: 500 MHz, 100X, 2.5 kV, Single-ended, BNC | Configure & Quote |
View Datasheet | P6015A | PROBE HIVOLTAGE; 75MHZ,40KV,1000X 10 FT – CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | TIVH02 | IsoVu optically isolated differential probe, 200 MHz, TekVPI, 3 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips | Configure & Quote |
View Datasheet | TIVH02L | IsoVu optically isolated differential probe, 200 MHz, TekVPI, 10 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips | Configure & Quote |
View Datasheet | TIVH05 | IsoVu optically isolated differential probe, 500 MHz, TekVPI, 3 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips | Configure & Quote |
View Datasheet | TIVH05L | IsoVu optically isolated differential probe, 500 MHz, TekVPI, 10 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips | Configure & Quote |
View Datasheet | TIVH08 | IsoVu optically isolated differential probe, 800 MHz, TekVPI, 3 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips | Configure & Quote |
View Datasheet | TIVH08L | IsoVu optically isolated differential probe, 800 MHz, TekVPI, 10 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips | Configure & Quote |
View Datasheet | TIVM1 | IsoVu optically isolated differential probe, 1 GHz, TekVPI, 3 m cable, includes 5X(IVTIP5X) and 25X(IVTIP25X) tips | Configure & Quote |
View Datasheet | TIVM1L | IsoVu optically isolated differential probe, 1 GHz, TekVPI, 10 m cable, includes 5X(IVTIP5X) and 25X(IVTIP25X) tips | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | P6330 | PROBE; DIFFERENTIAL; 3.5 GHZ BW, BNC, +/-1.75 V DIFFERENTIA.L DYNAMIC RANGE, +5V -4V COMMON MODE RANGE, 2.3 MV RMS NOISE AT INPUT, 5X ATTENTUATION-CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
View Datasheet | P7313SMA | 13 GHZ DIFFERENTIAL SIGNAL ACQUISITION SYSTEM WITH SMA INPUTS | Configure & Quote |
View Datasheet | P7330 | PROBE; DIFFERENTIAL; 3.5 GHz BW, +/-1.75 V DIFFERENTIA.L DYNAMIC RANGE, +5V -4V COMMON MODE RANGE, 2.3 MV RMS NOISE AT INPUT, 5X ATTENTUATION – CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
View Datasheet | P7350 | DIFFERENTIAL PROBE, 5 GHZ | Configure & Quote |
View Datasheet | P7380SMA | 8 GHZ DIFFERENTIAL SIGNAL ACQUISITION SYSTEM WITH SMA INPUTS,CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
View Datasheet | P7504 | 4GHz TRIMODE DIFFERENTIAL PROBE | Configure & Quote |
View Datasheet | P7506 | 6GHz TRIMODE DIFFERENTIAL PROBE | Configure & Quote |
View Datasheet | P7508 | 8GHz TRIMODE DIFFERENTIAL PROBE | Configure & Quote |
View Datasheet | P7513A | 13GHz TRIMODE DIFFERENTIAL PROBE | Configure & Quote |
View Datasheet | P7516 | TRIMODE DIFFERENTIAL PROBE. CERTIFICATE OF TRACEABLE CALIBRATION STANDARD WITH PRODUCT. | Configure & Quote |
P7520 | TRIMODE DIFFERENTIAL PROBE. CERTIFICATE OF TRACEABLE CALIBRATION STANDARD WITH PRODUCT. | Configure & Quote | |
View Datasheet | P7520A | TriMode Differential Probe | Configure & Quote |
View Datasheet | P7625 | 25 GHz LOW NOISE TRIMODE PROBE IN CASE WITH ACCESSORIES | Configure & Quote |
View Datasheet | P7630 | 30 GHz LOW NOISE TRIMODE PROBE IN CASE WITH ACCESSORIES | Configure & Quote |
View Datasheet | P7633 | 33 GHz LOW NOISE TRIMODE PROBE IN CASE WITH ACCESSORIES | Configure & Quote |
View Datasheet | P7708 | 8 GHz TriMode Probe with TekFlex connector technology, TekConnect interface | Configure & Quote |
View Datasheet | P7713 | 13 GHz TriMode Probe with TekFlex connector technology, TekConnect interface | Configure & Quote |
View Datasheet | P7716 | 16 GHz TriMode Probe with TekFlex connector technology, TekConnect interface | Configure & Quote |
View Datasheet | P7720 | 20 GHz TriMode Probe with TekFlex connector technology, TekConnect interface | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | DPO7OE1 | 33GHz, single/multi-mode optical probe for MSO/DPO70000 Real Time Oscilloscopes. Wavelength range: 750nm – 1650nm | Configure & Quote |
View Datasheet | DPO7OE2 | 59GHz, single mode optical probe for MSO/DPO70000 Real Time Oscilloscopes. Wavelength range: 1200nm – 1650nm | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | P6701B | O/E CONVERTER; DC-1GHZ, 500-950NM, TPI – CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
View Datasheet | P6703B | O/E CONVERTER; DC-1GHZ, 1100-1650NM, TPI – CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
Reviews
There are no reviews yet.